Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Water Res X ; 22019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30882067

RESUMO

Urban water and wastewater utilities are striving to improve their environmental and economic performances due to multiple challenges such as increasingly stringent quality criterion, aging infrastructure, constraining financial burden, growing urban population, climate challenges and dwindling resources. Growing needs of holistic assessments of urban water systems are required to identify systems-level cross-domain solutions. This study evaluated the life cycle environmental and economic impacts of urban water and wastewater systems with two utilities in Greater Cincinnati region as a case study. The scope of this study includes the entire urban water and wastewater systems starting from raw water acquisition for drinking water to wastewater treatment and discharge. The detailed process-based life cycle models were developed based on the datasets provided by local water and wastewater utilities. The life cycle assessment indicated that the operation and maintenance of drinking water distribution was a dominating contributor for energy consumption (43%) and global warming potential (41%). Wastewater discharge from the wastewater treatment plant contributed to more than 80% of the total eutrophication potential. The cost analysis determined that labor and maintenance cost (19%) for wastewater collection, and electricity cost (13%) for drinking water distribution were major contributors. Electricity purchased by the utility was the driver for the majority of impact categories assessed with the exception of eutrophication, blue water use, and metal depletion. Infrastructure requirements had a negligible influence on impact results, contributing less than 3% to most categories, with the exception of metal depletion where it led to 68% of total burdens. Sensitivity analysis showed that the life cycle environmental results were more sensitive to the choice of the electricity mixes and electricity consumption than the rest of input parameters such as chemical dosages, and infrastructure life time. This is one of the first comprehensive studies of the whole urban water system using real case data. It elucidates a bigger picture of energy, resource and cost distributions in a typical urban centralized water system. Inherent to a modern city as large population centers, a significant expenditure has to be invested to provide water services function (moving water, treating water/wastewater) in order to avoid human and environmental health problems. This study provides insights for optimization potentials of overall treatment efficiency and can serve as a benchmark for communities considering adoption of alternative water systems.

2.
Sci Total Environ ; 619-620: 1330-1339, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29734610

RESUMO

Drinking water treatment plants rely on purification of contaminated source waters to provide communities with potable water. One group of possible contaminants are enteric viruses. Measurement of viral quantities in environmental water systems are often performed using polymerase chain reaction (PCR) or quantitative PCR (qPCR). However, true values may be underestimated due to challenges involved in a multi-step viral concentration process and due to PCR inhibition. In this study, water samples were concentrated from 25 drinking water treatment plants (DWTPs) across the US to study the occurrence of enteric viruses in source water and removal after treatment. The five different types of viruses studied were adenovirus, norovirus GI, norovirus GII, enterovirus, and polyomavirus. Quantitative PCR was performed on all samples to determine presence or absence of these viruses in each sample. Ten DWTPs showed presence of one or more viruses in source water, with four DWTPs having treated drinking water testing positive. Furthermore, PCR inhibition was assessed for each sample using an exogenous amplification control, which indicated that all of the DWTP samples, including source and treated water samples, had some level of inhibition, confirming that inhibition plays an important role in PCR-based assessments of environmental samples. PCR inhibition measurements, viral recovery, and other assessments were incorporated into a Bayesian model to more accurately determine viral load in both source and treated water. Results of the Bayesian model indicated that viruses are present in source water and treated water. By using a Bayesian framework that incorporates inhibition, as well as many other parameters that affect viral detection, this study offers an approach for more accurately estimating the occurrence of viral pathogens in environmental waters.


Assuntos
Água Potável/virologia , Monitoramento Ambiental , Modelos Estatísticos , Poluição da Água/estatística & dados numéricos , Teorema de Bayes , Estados Unidos , Microbiologia da Água , Purificação da Água/estatística & dados numéricos
3.
Water Res ; 109: 207-216, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27889622

RESUMO

A dual-wavelength UV-C LED unit, emitting at peaks of 260 nm, 280 nm, and the combination of 260|280 nm together was evaluated for its inactivation efficacy and energy efficiency at disinfecting Escherichia coli, MS2 coliphage, human adenovirus type 2 (HAdV2), and Bacillus pumilus spores, compared to conventional low-pressure and medium-pressure UV mercury vapor lamps. The dual-wavelength unit was also used to measure potential synergistic effects of multiple wavelengths on bacterial and viral inactivation and DNA and RNA damage. All five UV sources demonstrated similar inactivation of E. coli. For MS2, the 260 nm LED was most effective. For HAdV2 and B. pumilus, the MP UV lamp was most effective. When measuring electrical energy per order of reduction, the LP UV lamp was most efficient for inactivating E. coli and MS2; the LP UV and MP UV mercury lamps were equally efficient for HAdV2 and B. pumilus spores. Among the UV-C LEDs, there was no statistical difference in electrical efficiency for inactivating MS2, HAdV2, and B. pumilus spores. The 260 nm and 260|280 nm LEDs had a statistical energy advantage for E. coli inactivation. For UV-C LEDs to match the electrical efficiency per order of log reduction of conventional LP UV sources, they must reach efficiencies of 25-39% or be improved on by smart reactor design. No dual wavelength synergies were detected for bacterial and viral inactivation nor for DNA and RNA damage.


Assuntos
Desinfecção , Escherichia coli , Humanos , Levivirus , Raios Ultravioleta , Purificação da Água
4.
J Virol Methods ; 237: 200-203, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27596270

RESUMO

Cell culture based assays used to detect waterborne viruses typically call for incubating the sample for at least two weeks in order to ensure that all the culturable virus present is detected. Historically, this estimate was based, at least in part, on the length of time used for detecting poliovirus. In this study, we have examined A549 cells infected with human adenovirus type 2, and have found that a three week incubation of virus infected cells results in a higher number of detected viruses by quantal assay than what is seen after two weeks of incubation, with an average 955% increase in Most Probable Number (MPN) from 2 weeks to 3 weeks. This increase suggests that the extended incubation time is essential for accurately estimating viral titer, particularly for slow-growing viruses, UV treated samples, or samples with low titers of virus. In addition, we found that for some UV-treated samples, there was no detectable MPN at 2 weeks, but after 3 weeks, MPN values were obtained. For UV-treated samples, the average increase in MPN from 2 weeks to 3 weeks was 1401%, while untreated samples averaged a change in MPN of 674%, leading us to believe that the UV-damaged viral DNA may be able to be repaired such that viral replication then occurs.


Assuntos
Adenoviridae/crescimento & desenvolvimento , Carga Viral/métodos , Células A549 , Adenoviridae/efeitos da radiação , Adenovírus Humanos/crescimento & desenvolvimento , Adenovírus Humanos/efeitos da radiação , Linhagem Celular , Humanos , Fatores de Tempo , Raios Ultravioleta , Replicação Viral
5.
J Vis Exp ; (115)2016 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-27684193

RESUMO

A standardized method is required when national studies on virus occurrence in environmental and drinking waters utilize multiple analytical laboratories. The U.S Environmental Protection Agency's (USEPA) Method 1615 was developed with the goal of providing such a standard for measuring Enterovirus and Norovirus in these waters. Virus is concentrated from water using an electropositive filter, eluted from the filter surface with beef extract, and then concentrated further using organic flocculation. Herein we present the protocol from Method 1615 for filter elution, secondary concentration, and measurement of total culturable viruses. A portion of the concentrated eluate from each sample is inoculated onto ten replicate flasks of Buffalo Green Monkey kidney cells. The number of flasks demonstrating cytopathic effects is used to quantify the most probable number (MPN) of infectious units per liter. The method uses a number of quality controls to increase data quality and to reduce interlaboratory and intralaboratory variation. Laboratories must meet defined performance standards. Method 1615 was evaluated by examining virus recovery from reagent-grade and ground waters seeded with Sabin poliovirus type 3. Mean poliovirus recoveries with the total culturable assay were 111% in reagent grade water and 58% in groundwaters.


Assuntos
Água Potável/virologia , Enterovirus/isolamento & purificação , Água Subterrânea/virologia , Norovirus/isolamento & purificação , Animais , Bovinos , Linhagem Celular , Chlorocebus aethiops , Enterovirus/genética , Norovirus/genética , Poliovirus/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Estados Unidos , United States Environmental Protection Agency , Microbiologia da Água
6.
J Vis Exp ; (107): e52646, 2016 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-26862985

RESUMO

EPA Method 1615 measures enteroviruses and noroviruses present in environmental and drinking waters. This method was developed with the goal of having a standardized method for use in multiple analytical laboratories during monitoring period 3 of the Unregulated Contaminant Monitoring Rule. Herein we present the protocol for extraction of viral ribonucleic acid (RNA) from water sample concentrates and for quantitatively measuring enterovirus and norovirus concentrations using reverse transcription-quantitative PCR (RT-qPCR). Virus concentrations for the molecular assay are calculated in terms of genomic copies of viral RNA per liter based upon a standard curve. The method uses a number of quality controls to increase data quality and to reduce interlaboratory and intralaboratory variation. The method has been evaluated by examining virus recovery from ground and reagent grade waters seeded with poliovirus type 3 and murine norovirus as a surrogate for human noroviruses. Mean poliovirus recoveries were 20% in groundwaters and 44% in reagent grade water. Mean murine norovirus recoveries with the RT-qPCR assay were 30% in groundwaters and 4% in reagent grade water.


Assuntos
Enterovirus/isolamento & purificação , Água Subterrânea/virologia , Norovirus/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Microbiologia da Água , Animais , Enterovirus/genética , Humanos , Camundongos , Norovirus/genética , Poliovirus/genética , Poliovirus/isolamento & purificação , RNA Viral/genética , Abastecimento de Água
7.
J Microbiol Methods ; 122: 43-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26825005

RESUMO

Recent studies have demonstrated the potential to use Bacillus pumilus endospores as a surrogate for human adenovirus (HAdV) in UV disinfection studies. The use of endospores has been limited by observations of batch-to-batch variation in UV sensitivity. This study reports on a propagation method that utilizes a commercially available medium to produce UV tolerant B. pumilus endospores with a consistent UV sensitivity. It is further demonstrated that the endospores of B. pumilus strain (ATCC 27142), produced using this protocol (half strength Columbia broth, 5 days incubation, with 0.1mM MnSO4), display a UV dose-response that is similar to that of HAdV. Endospore stocks could be stored in ethanol for up to two months at 4 °C without a significant change in UV sensitivity. Synergistic endospore damage was observed by pre-heat treatment of water samples followed by UV irradiation. UV tolerant B. pumilus endospores are a potential surrogate of HAdV for UV treatment performance tests in water utilities which do not have in-house research virology laboratories.


Assuntos
Adenovírus Humanos/efeitos da radiação , Bacillus/efeitos da radiação , Esporos Bacterianos/efeitos da radiação , Inativação de Vírus/efeitos da radiação , Linhagem Celular , Desinfecção/métodos , Relação Dose-Resposta à Radiação , Escherichia coli/efeitos da radiação , Temperatura Alta , Humanos , Levivirus/efeitos da radiação , Tolerância a Radiação , Esporos Bacterianos/efeitos dos fármacos , Esporos Bacterianos/crescimento & desenvolvimento , Raios Ultravioleta , Microbiologia da Água , Purificação da Água/métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-26030683

RESUMO

Practical difficulties of the traditional adenovirus infectivity assay such as intensive labor requirements and longer turnaround period limit the direct use of adenovirus as a testing microorganism for systematic, comprehensive disinfection studies. In this study, we attempted to validate the applicability of integrated cell culture quantitative PCR (ICC-qPCR) as an alternative to the traditional cell culture method with human adenovirus type 2 (HAdV2) in a low-pressure UV disinfection study and to further optimize the procedures of ICC-qPCR for 24-well plate format. The relatively high stability of the hexon gene of HAdV2 was observed after exposure to UV radiation, resulting in a maximum gene copy reduction of 0.5 log10 at 280 mJ cm(-2). Two-day post-inoculation incubation period and a maximum spiking level of 10(5) MPN mL(-1) were selected as optimum conditions of ICC-qPCR with the tested HAdV2. An approximate 1:1 correlation of virus quantities by the traditional and ICC-qPCR cell culture based methods suggested that ICC-qPCR is a satisfactory alternative for practical application in HAdV2 disinfection studies. ICC-qPCR results, coupled with a first-order kinetic model (i.e., the inactivation rate constant of 0.0232 cm(2) mJ(-1)), showed that an UV dose of 172 mJ cm(-2) achieved a 4-log inactivation credit for HAdV2. This estimate is comparable to other studies with HAdV2 and other adenovirus respiratory types. The newly optimized ICC-qPCR shows much promise for further study on its applicability of other slow replicating viruses in disinfection studies.


Assuntos
Infecções por Adenoviridae/prevenção & controle , Adenoviridae/isolamento & purificação , Adenoviridae/efeitos da radiação , Células Cultivadas/efeitos da radiação , Desinfecção/métodos , Raios Ultravioleta , Técnicas de Cultura de Células/normas , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos
9.
J Vis Exp ; (97)2015 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-25867928

RESUMO

EPA Method 1615 was developed with a goal of providing a standard method for measuring enteroviruses and noroviruses in environmental and drinking waters. The standardized sampling component of the method concentrates viruses that may be present in water by passage of a minimum specified volume of water through an electropositive cartridge filter. The minimum specified volumes for surface and finished/ground water are 300 L and 1,500 L, respectively. A major method limitation is the tendency for the filters to clog before meeting the sample volume requirement. Studies using two different, but equivalent, cartridge filter options showed that filter clogging was a problem with 10% of the samples with one of the filter types compared to 6% with the other filter type. Clogging tends to increase with turbidity, but cannot be predicted based on turbidity measurements only. From a cost standpoint one of the filter options is preferable over the other, but the water quality and experience with the water system to be sampled should be taken into consideration in making filter selections.


Assuntos
Enterovirus/isolamento & purificação , Norovirus/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Microbiologia da Água , Enterovirus/genética , Filtração/métodos , Norovirus/genética , Estados Unidos , United States Environmental Protection Agency , Água/análise
10.
Water Res ; 77: 155-169, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25864006

RESUMO

Planning for sustainable community water systems requires a comprehensive understanding and assessment of the integrated source-drinking-wastewater systems over their life-cycles. Although traditional life cycle assessment and similar tools (e.g. footprints and emergy) have been applied to elements of these water services (i.e. water resources, drinking water, stormwater or wastewater treatment alone), we argue for the importance of developing and combining the system-based tools and metrics in order to holistically evaluate the complete water service system based on the concept of integrated resource management. We analyzed the strengths and weaknesses of key system-based tools and metrics, and discuss future directions to identify more sustainable municipal water services. Such efforts may include the need for novel metrics that address system adaptability to future changes and infrastructure robustness. Caution is also necessary when coupling fundamentally different tools so to avoid misunderstanding and consequently misleading decision-making.


Assuntos
Conservação dos Recursos Naturais , Eliminação de Resíduos Líquidos/métodos , Recursos Hídricos/provisão & distribuição , Planejamento de Cidades , Monitoramento Ambiental , Modelos Teóricos , Abastecimento de Água/métodos , Abastecimento de Água/estatística & dados numéricos
11.
J Virol Methods ; 193(1): 140-6, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23727118

RESUMO

Enteroviruses, noroviruses and adenoviruses are among the most common viruses infecting humans worldwide. These viruses are shed in the feces of infected individuals and can accumulate in wastewater, making wastewater a source of a potentially diverse group of enteric viruses. In this study, two procedures were evaluated to concentrate noroviruses, adenoviruses and enteroviruses from primary effluent of wastewater. In the first procedure, indigenous enteroviruses, noroviruses and adenoviruses were concentrated using celite (diatomaceous earth) followed by centrifugation through a 30K MWCO filter and nucleic acid extraction. The second procedure used celite concentration followed by nucleic acid extraction only. Virus quantities were measured using qPCR. A second set of primary effluent samples were seeded with Coxsackievirus A7, Coxsackievirus B1, poliovirus 1 or enterovirus 70 before concentration and processed through both procedures for recovery evaluation of enterovirus species representatives. The pairing of the single step extraction procedure with the celite concentration process resulted in 47-98% recovery of examined viruses, while the celite concentration process plus additional centrifugal concentration before nucleic acid extraction showed reduced recovery (14-47%). The celite concentration process followed by a large volume nucleic acid extraction technique proved to be an effective procedure for recovering these important human pathogens from wastewater.


Assuntos
Adenovírus Humanos/isolamento & purificação , Terra de Diatomáceas/química , Enterovirus/isolamento & purificação , Norovirus/isolamento & purificação , Virologia/métodos , Águas Residuárias/virologia , Centrifugação/métodos , Filtração/métodos , Humanos , Ácidos Nucleicos/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real
12.
Appl Environ Microbiol ; 79(1): 215-23, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23087037

RESUMO

The U.S. EPA developed a sample concentration and preparation assay in conjunction with the total culturable virus assay for concentrating and measuring culturable viruses in source and drinking waters as part of the Information Collection Rule (ICR) promulgated in 1996. In an effort to improve upon this method, the U.S. EPA recently developed Method 1615: Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. Method 1615 uses a culturable virus assay with reduced equipment and labor costs compared to the costs associated with the ICR virus method and introduces a new molecular assay for the detection of enteroviruses and noroviruses by reverse transcription-quantitative PCR. In this study, we describe the optimization of several new components of the molecular assay and examine virus recovery from ground, reagent-grade, and surface water samples seeded with poliovirus type 3 and murine norovirus. For the culturable virus and molecular assays, mean poliovirus recovery using the complete method was 58% and 20% in groundwater samples, 122% and 39% using low-titer spikes in reagent-grade water, 42% and 48% using high-titer spikes in reagent-grade water, and 11% and 10% in surface water with high turbidity, respectively. Murine norovirus recovery by the molecular assay was 30% in groundwater samples, less than 8% in both low- and high-titer spikes in reagent-grade water, and 6% in surface water with high turbidity. This study demonstrates the effectiveness of Method 1615 for use with groundwater samples and highlights the need for further research into its effectiveness with surface water.


Assuntos
Norovirus/isolamento & purificação , Poliovirus/isolamento & purificação , Virologia/métodos , Microbiologia da Água , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Cultura de Vírus/métodos
13.
J Virol Methods ; 179(2): 423-8, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22138439

RESUMO

The effective recovery of adenovirus from water is a critical first step in developing a virus occurrence method able to provide accurate data for risk assessments and other applications. During virus concentration, electropositive filters are typically eluted with beef extract, undergo secondary concentration using either an organic flocculation or polyethylene glycol (PEG) precipitation technique and are ultimately resuspended in sodium phosphate buffer. In this study, an alternative secondary concentration procedure using celite was optimized by identifying the optimal celite and elution buffer to use. Two elution buffers, sodium phosphate and 1× PBS, were evaluated for their impact on real-time PCR. Sodium phosphate produced high levels of PCR inhibition compared to 1× PBS and so 1× PBS was used in subsequent experiments. The two secondary concentration techniques that were tested with adenovirus 40 and 41 gave recoveries of 69% and 65% for the optimized celite method and 75% and 109% for the organic flocculation method, respectively. Fine particle, calcinated celites in combination with 1× PBS elution buffer were shown to be effective at concentrating adenovirus 40 and 41 during secondary concentration and their subsequent detection using PCR. Heat extraction efficiencies were compared to samples processed using a DNA extraction kit to address possible virus aggregation issues. Samples processed through DNA extraction were found to produce realistic adenovirus recoveries compared to exaggerated recoveries using heat extraction.


Assuntos
Adenoviridae/isolamento & purificação , Terra de Diatomáceas , Manejo de Espécimes/métodos , Virologia/métodos , Microbiologia da Água , Animais , Soluções Tampão , Humanos
14.
Ground Water ; 49(1): 98-110, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20331750

RESUMO

A survey of enteric viruses and indicator bacteria was carried out in eight community water supply sources (four wells and four springs) in East Tennessee. Seven sites derived their water from carbonate aquifers and one from fractured sandstone. Four of the sites were deemed "low-risk" based on prior monitoring of fecal indicators and factors such as presence of thick layers of overlying sediments. The remaining sites were deemed "high-risk." Enteric viruses (enterovirus and reovirus) were detected by cell culture at least once in seven of the eight wells or springs including all but one of the four low-risk sites. Viral RNA, however, was not detected in any of the samples by reverse transcription-polymerase chain reaction. Conventional indicators of microbial contamination (Escherichia coli and total coliform bacteria) were detected together with culturable viruses in seven of nine virus positive samples. Bacteroides, an alternative fecal indicator which has not previously been used in groundwater investigations, was also detected in all but one of the samples containing E. coli or total coliform bacteria, as well as in one sample where viruses were present in the absence of other bacterial indicators. The study highlights some of the challenges involved in surveys of virus occurrence and indicates that culturable enteric viruses in East Tennessee karst aquifers may be more widespread than previously observed in studies of karst aquifers in Pennsylvania (8%), the Ozark region of Missouri (< 1%), or several other states covered in a national microbial water quality survey conducted by the U.S. Environmental Protection Agency (43%).


Assuntos
Bactérias/isolamento & purificação , Vírus/isolamento & purificação , Microbiologia da Água , Abastecimento de Água/análise , Tennessee
15.
J Virol Methods ; 132(1-2): 13-7, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16194574

RESUMO

Electropositively charged filters are frequently used for concentrating enteric viruses from large volumes of water. A major disadvantage to the use of these filters, however, is that they are not cost-effective. At US$ 150-180 per filter, routine viral monitoring of water is cost-prohibitive. This study describes the development of a method which allows a filter to be used up to three times, achieving comparable recoveries to new filters. Zetapor 1MDS and N66 Posidyne electropositive filters were tested. The method was analyzed using tap water and Ohio River water that was spiked with poliovirus. Tap water recoveries averaged 32% for new filters, 30% for filters used twice, and 38% for filters used three times. River water recoveries averaged 68% for new filters, 83% for filters used twice, and 100% for filters used three times. RT-PCR and dot-blot hybridization were performed on sample concentrates to ensure that all viral nucleic acid from the previous test had been removed from the filters by the treatment process.


Assuntos
Filtração/métodos , Vírus/isolamento & purificação , Microbiologia da Água , Hibridização de Ácido Nucleico , Poliovirus/genética , Poliovirus/isolamento & purificação , RNA Viral/análise , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Rios/virologia , Eletricidade Estática , Ensaio de Placa Viral
16.
J Virol Methods ; 121(1): 39-48, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15350731

RESUMO

Enteric viruses often contaminate water sources causing frequent outbreaks of gastroenteritis. Reverse transcription-polymerase chain reaction (RT-PCR) assays are commonly used for detection of human enteric viruses in environmental and drinking water samples. RT-PCR provides a means to rapidly detect low levels of these viruses, but it is sensitive to inhibitors that are present in water samples. Inhibitors of RT-PCR are concentrated along with viruses during sample processing. While procedures have been developed to remove inhibitors, none of them completely remove all inhibitors from all types of water matrices. This problem requires that adequate controls be used to distinguish true from potentially false-negative results. To address this problem, we have developed homologous viral internal controls for hepatitis A virus (HAV), poliovirus, Norwalk virus and rotavirus. These internal controls can be used in RT-PCR assays for the detection of the above viruses by competitive amplification, thereby allowing the detection of false negatives in processed water samples. The internal controls developed in this study were successfully tested with virus-seeded environmental water sample concentrates.


Assuntos
Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , Vírus/isolamento & purificação , Microbiologia da Água , Eletroforese em Gel de Poliacrilamida , Reações Falso-Negativas , Gastroenterite/virologia , Vírus da Hepatite A/genética , Vírus da Hepatite A/isolamento & purificação , Vírus Norwalk/genética , Vírus Norwalk/isolamento & purificação , Hibridização de Ácido Nucleico , Poliovirus/genética , Poliovirus/isolamento & purificação , RNA Viral/análise , RNA Viral/isolamento & purificação , Padrões de Referência , Rotavirus/genética , Rotavirus/isolamento & purificação , Vírus/genética
17.
Can J Microbiol ; 50(4): 269-78, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15213751

RESUMO

Astrovirus is a common cause of gastroenteritis in humans that has been determined to be responsible for outbreaks of illness in several countries. Since astrovirus can be waterborne, it is important to be able to identify this virus in environmental water. We have developed and optimized a reverse transcription - polymerase chain reaction (RT-PCR) method that was able to amplify all eight astrovirus serotypes in a single reaction. In addition, a positive control construct was designed so that any inhibitors of this astrovirus assay could be detected. The assay was adapted for use in a real-time PCR assay and the sensitivity of these two methods was compared. The real-time assay was then combined with CaCo2 cell culture to produce an integrated cell culture/RT-PCR (ICC/RT-PCR) assay that was able to detect low levels of astrovirus after an incubation of 7 days or less. Also, the sensitivity of the ICC/RT-PCR assay was compared with RT-PCR alone. The methods were used to detect astrovirus in acute phase illness stool samples as well as in a water sample spiked with astrovirus.


Assuntos
Mamastrovirus/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Células CACO-2 , Células Cultivadas , Humanos , Mamastrovirus/classificação , Mamastrovirus/genética , Mamastrovirus/crescimento & desenvolvimento , Filogenia , RNA Viral/análise , Sensibilidade e Especificidade
18.
J Infect Dis ; 187(2): 303-6, 2003 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-12552455

RESUMO

In February 2001, episodes of acute gastroenteritis were reported to the Wyoming Department of Health from persons who had recently vacationed at a snowmobile lodge in Wyoming. A retrospective cohort study found a significant association between water consumption and illness, and testing identified Norwalk-like virus (NLV) in 8 of 13 stool samples and 1 well. Nucleotide sequences from the positive well-water specimen and 6 of the positive stool samples were identical. This multistrain NLV outbreak investigation illustrates the importance of NLV as a cause of waterborne illness and should encourage monitoring for NLVs in drinking water.


Assuntos
Infecções por Caliciviridae/epidemiologia , Infecções por Caliciviridae/virologia , Surtos de Doenças , Norovirus/isolamento & purificação , Microbiologia da Água , Estudos de Coortes , Ingestão de Líquidos , Fezes/virologia , Gastroenterite/epidemiologia , Gastroenterite/virologia , Humanos , Veículos Off-Road , Estudos Retrospectivos , Fatores de Tempo , Abastecimento de Água , Wyoming/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...